The Drager Apollo Anesthesia Machine includes a built-in gas module, built-in gas (anesthetic agents, CO2, O2) display, container of Sodasorb, new O2 sensor, two new flow sensors, two new batteries, and a power cord. It is in excellent condition and certified to proper operating specifications.
4 Fabius GS Operator’s Manual Part Number: 4117102-005 Rev: — Restriction Caution: Federal law and regulations in the United States restrict this device to sale by, or on the order of, a physician. Intended Use Fabius GS is an inhalation anesthesia machine for use in operating, induction and recovery rooms. Ford mustang repair manual.
Note: Patient vital signs module and vaporizers pictured are sold separately.
Warranty: 1 Year.
From the reliable line of Drager medical products comes the Apollo Anesthesia Machine. With a heightened emphasis on cost reduction in healthcare, Drager anesthesia solutions help you reduce operating costs and maximize reimbursement.
The Drager Apollo Anesthesia Machine can play an important role in optimizing your anesthesia workflow and reducing process costs with features such as the fully automatic self-test. Little user interaction is required allowing the caregiver to focus more on the patient.
In addition to providing you with invaluable assistance through best-in-class therapy, Apollo also offers you an open-platform architecture - enabling it to be easily integrated into your overall workflow. The Apollo features a built-in gas and O2 monitor. You can monitor gasses and O2 levels through the built-in display, meaning the only auxiliary monitor needed is a vital signs monitor.
FeaturesDrager Apollo Anesthesia Machine Features
- Advanced Ventilation: The Apollo Anesthesia Machine has the ventilation technology to support patients of any age and acuity. The E-Vent plus servo controlled high-speed piston ventilator works with great precision to supply a maximum peak flow far in excess of any bellows ventilator, resulting in the kind of performance previously only seen in the ICU. Additionally, unlike a bellows ventilator, it requires no drive gas. The very short response time has clear physiological benefits for your patients, while the digital precision helps you make the most of the latest ventilation modes.
- Unique Low-Flow Wizard: The Apollo is designed to support the user by providing optimal low and minimal flow settings. The consistent use of low-flow anesthesia techniques can significantly reduce the cost of inhalation anesthetic agents. Reducing the fresh gas flow from 3 L/min to 1 L/min can result in anesthetic agent savings of up to 50%.
- Automated Startup:
- Simple straightforward startup makes it easier for the staff and provides complete information on device status.
- Enhanced troubleshooting with clear text directions.
- Integrated breathing system eliminates external hoses and clutter, reducing the risk of misconnection and disconnection.
- Fully automatic self-test lasts approximately three minutes, reflects the results to the user, and makes results available to the user at any time.
- Volume AutoFlow (AF) Mode (optional): Combines the advantages of pressure- and volume controlled ventilation. This mode uses a decelerated inspiratory flow in order to achieve the lowest possible pressure without pressure peaks.
- Guaranteed tidal volume.
- Automatic adaption of inspiratory pressure to changed lung conditions.
- Lung-protective ventilation used consistently, even in volume controlled mode.
- Volume Mode Autoflow can be used with synchronization and optional pressure support.
- Monitoring:
- Standard: Inspiratory and expiratory concentration of O2, N2O, CO2 as well as anesthetic agents (Halothane, Enflurane, Isoflurane, Sevoflurane, Desflurane); Minute volume (MV) and Tidal volume (VT); Breathing frequency; Peak pressure, plateau pressure, mean pressure, PEEP; Patient compliance CPAT.
- Optional: Functional oxygen saturation (SpO2).
- The following parameters maybe displayed as waveforms:
- Standard: Concentration of CO2, O2, as well as anesthetic agents, airway pressure, inspiratory and expiratory flow.
- Optional: Plethysmogram; Bar graph display of volumeter and tidal volume; Virtual flow tubes for O2, AIR, N2O; Display of graphical trends and numerical lists of measured values; AutoSet for alarm limits.
SpecificationsDrager Apollo Anesthesia Machine Specifications
- Weight: 365 lb (165 kg) without vaporizers and gas cylinders.
- Dimensions: 59' (H) x 33.5' (W) x 31.5' (D) (150 cm x 85 cm x 80 cm).
- Power: 200 W, typically.
- Operating Voltage: 100 to 127 VAC (-15% + 10%), 45 - 65 Hz.
- Integrated Power Backup: At least 30 min, typically 90 min; Depending on ventilation parameters.
- Ventilator E-Vent plus: Electrically driven and electronically controlled, fresh gas decoupled.
- Ventilation Modes:
- Standard: Manual, spontaneous, Volume Mode, Pressure Mode.
- Optional/Synchronization: Pressure Support (PS), Volume Mode Autoflow.
- Pressure Limitation PMAX (in Volume Mode): (PEEP + 10) up to 70 cmH2O.
- Pressure Limitation PINSP (in Pressure Mode): (PEEP + 5) up to 70 cmH2O.
- Trigger: 0.3 - 15 L/min.
- Tidal Volume VT (compliance compensated) (in Volume Mode):
- Standard: 20 - 1400 mL.
- With Advanced Ventilation option: 5 - 1400 mL.
- Breathing Frequency: 3 - 100 bpm.
- Inspiration Time (TINSP): 0.2 - 6.7 s.
- Inspiration/Expiration Time Ratio (I:E): 5:1 max.
- Plateau Time (TIP:TINSP): 0 - 60%.
- Inspiratory Flow (in Pressure Mode): 150 L/min max.
- PEEP:
- In Volume Mode: 0 - 20 cmH2O (max. PMAX - 10 cmH2O).
- In Pressure Mode: 0 - 20 cmH2O (max. PINSP - 5 cmH2O).
- Fresh-Gas Flow: 0 - 10 L/min for each gas (oxygen, air, nitrous oxide).
- TSLOPE (in Pressure Mode and Pressure Support): 0 - 2 s.
- Total System Leakage: < 150 mL/min at 30 cmH2O (automatic leak test).
- O2 Flow Control: Sensitive ORC Function: At least 21 Vol.-% with N2O as carrier gas.
- O2 Flush: > 35 L/min.
- Serial Interface: 2 x RS 232.
- Protocol: Medibus, Medibus X.
- Absorber Volume (reusable canister): 1.5 L.
LiteratureDrager Apollo Anesthesia Machine Literature
Drager Product Information: Apollo Software 4.5
Drager Apollo Anesthesia Workstation Brochure
Drager Apollo User Manual
Anaesthesia machines, vaporizer, blender, circle absorbtion systems, workstations and extension modules.
Ventilators and humidifier see the Ventilators section.
Anaesthesia machines of GE and Datex Ohmeda might be identical.
Aeonmed Aeon 7400
User manual
Drager Anesthesia Machines User Guide
1.2 MB Download
Aeonmed Aeon 7500
User manual
2.3 MB Download
Aeonmed VP-300 Vaporizer
User manual
4.2 MB Download
Beijing Eternity AM852 Veterinary
User manual
830 KB Download
Blease Datum L Vaporizer
User manual
1.1 MB Download
Datex-Ohmeda Aespire 7900
User reference manual (Part 1)
2.0 MB Download
Datex-Ohmeda Aespire 7900
User reference manual (Part 2)
1.4 MB Download
Datex-Ohmeda Aestiva
User manual (part 2)
5.9 MB Download
Datex-Ohmeda Avance
User reference manual
10.4 MB Download
Datex Ohmeda Excel 210
User manual
490 KB Download
Datex-Ohmeda S/5 Aespire
Cleaning and Maintenance
80.0 MB Download
Datex-Ohmeda Tec 7 Vaporiser
User manual
1.2 MB Download
Datex-Ohmeda Tec 6 Plus Vaporizer
User manual
630 KB Download
Diamedica Glostavent Helix
User manual
1.6 MB Download
Diamedica DPA-02
User manual
395 KB Download
Dräger Apollo
User manual
10.1 MB Download prohibited by Dräger. Support is not desired.
Dräger Cicero EM
User manual
1.7 MB Download prohibited by Dräger. Support is not desired.
Dräger - Circle Absorption System 7a
User manual
7.6 MB Download prohibited by Dräger. Support is not desired.
Dräger - Kreissystem 7a
User Manual
9.2 MB Download prohibited by Dräger. Support is not desired.
Dräger - Kreissystem 8
Technische Beschreibung
25.6 MB Download prohibited by Dräger. Support is not desired.
Dräger - Circle Absorbtion System 8
Technical description
25.6 MB Download prohibited by Dräger. Support is not desired.
Dräger D-Vapor Desflurane Vaporiser
User manual
2.0 MB Download prohibited by Dräger. Support is not desired.
Dräger Evita XL
User manual
6.5 MB Download prohibited by Dräger. Support is not desired.
Dräger Evita XL
Quick user manual
130 KB Download prohibited by Dräger. Support is not desired.
Dräger Evita XL, XL Neo
User manual
11.6 MB Download prohibited by Dräger. Support is not desired.
Dräger Fabius CE
User manual
3.4 MB Download prohibited by Dräger. Support is not desired.
Dräger Fabius Tiro
User manual
5.9 MB Download prohibited by Dräger. Support is not desired.
Dräger Narkomed GS
User manual
1.8 MB Download prohibited by Dräger. Support is not desired.
Dräger Narkomed 6400
User manual
4.2 MB Download prohibited by Dräger. Support is not desired.
Dräger Narkomed Mobile
User manual
2.0 MB Download prohibited by Dräger. Support is not desired.
Dräger Oxydig O2 Meter
User manual
1.0 MB Download prohibited by Dräger. Support is not desired.
Dräger Primus
User manual
4.8 MB Download prohibited by Dräger. Support is not desired.
Drager Apollo User Manual
Dräger Seneca
User manual
5.1 MB Download prohibited by Dräger. Support is not desired.
Dräger Sulla 808
User manual
23.3 MB Download prohibited by Dräger. Support is not desired.
Dräger Trajan 808
User manual
2.8 MB Download prohibited by Dräger. Support is not desired.
Dräger Titus
User manual
1.2 MB Download prohibited by Dräger. Support is not desired.
Dräger Vapor 19.n
User manual
1.1 MB Download prohibited by Dräger. Support is not desired.
Dräger Vapor 2000
Instruction manual
4.0 MB Download prohibited by Dräger. Support is not desired.
Dräger Ventilog
User manual
21.2 MB Download prohibited by Dräger. Support is not desired.
Dräger Ventilog 2
User manual
950 KB Download prohibited by Dräger. Support is not desired.
GE Aisys
User manual
12.7 MB Download
GE Tec 6 Plus
User manual
2.2 MB Download
Gradian Universal
User manual
780 KB DownloadWith friendly support of Gradian. More info here.
Gradian Universal
Apollo Anesthesia Machine User Manual
User manual
900 KB DownloadWith friendly support of Gradian. More info here.
Hersill KAV 1
User manual
407 KB Download
Heyer - Anaesthetic Gas Evacuation System
Operating instructions
275 KB Download
Heyer Narkomat+
User manual
6.2 MB Download
Heyer Modular
User manual
1.6 MB Download
Heyer Pasithel
User manual
4.9 MB Download
Maquet Servo 900
Operating manual
2.0 MB Download
Mindray does not support the correct usage of their older equipment. (???)
But at least the user manuals of the latest models can be downloaded here.
Mindray A3-A5
User manual
3.7 MB Download prohibited by Mindray.
Mindray Wato EX-65
User manual
17.8 MB Download prohibited by Mindray.
Mindray Wato EX-65
Quick user manual
1.2 MB Download prohibited by Mindray.
OES Draw Over Vaporizer
User and maintenance manual
640 KB Download
Ohmeda Tec 6 Vaporizer
User and maintenance manual
3.0 MB Download
Penlon A100 Circle Absorber
User manual
4.6 MB Download
Penlon A-200 SP Circle Absorber
User manual
1.2 MB Download
Penlon AM1000
User manual
3.5 MB Download
Penlon (Paragon) AV-S Ventilator
User manual
400 KB Download
Penlon EMO
User manual
1.4 MB Download
Penlon OMV Fifty Vaporizer
User manual
440 KB Download
Penlon Prima SP
User manual
2.8 MB Download
Penlon Prima SP2
User manual
430 KB Download
Penlon Prima SP3
User manual
540 KB Download
Penlon Sigma Delta Vaporizer
User manual
230 KB Download
Penlon Vapor
Instruction manual
1.1 MB Download
Sechrist 3500 Blender
User manual
1.4 MB Download
Stephan Anaesthesia System ISO
User manual
2.1 MB Download
Stephan Artec
User manual 1999
630 KB Download
Stephan Artec
User manual 2010
530 KB Download
Taema Monnal D2
User manual
630 KB Download
Taema Monnal D2
User manual
630 KB Download
Ulco AB-800 Absorber
User manual
1.7 MB Download
Ulco Elite 615
User manual
650 KB Download
Ulco Integrus PSV
User manual
6.2 MB Download
Ulco Signet 615
User manual
1.0 MB Download